Current research projects

Image Service offer for Leak Detection and Tightness Test
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Calibration leak for the water bath leak test
Image Helium extraction from natural gas
Image Practical training, diploma, master, bachelor
Image Combined building and system simulation
Image Tribological investigations of oil-refrigerant-material-systems
Image Measurements on ceiling mounted cooling systems
Image 3D - Air flow sensor
Image Hydrogen and methane testing field at the ILK
Image Non- invasive flow measurements
Image Energy efficiency consulting - cogeneration systems
Image Brine (water)-water heat pump
Image Innovative Parahydrogen Generator Based on Magnets
Image Laseroptical measurement

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects

Image

Humidifier System for High-Purity Gases

Nafion - moisture transfer

Image

Behavior of multiphase cryogenic fluids

experimental und numerical investigations

Image

Innovative Parahydrogen Generator Based on Magnets

Magnetic Gas Separation of the Hydrogen Isomers

Image

Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K

high performance efficiency, environmental friendliness, compactness, cost-effectiveness