Current research projects

Image Panel with indirect evaporative cooling via membrane
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Cool Up
Image Verification of storage suitability of cryo tubes
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Testing of mobile leak detectors according to DIN EN 14624
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Refrigerants, lubricants and mixtures
Image Ionocaloric cooling
Image Behavior of multiphase cryogenic fluids
Image Hydrogen and methane testing field at the ILK
Image All-in-one device for freeze-drying and production of biomaterial
Image Practical training, diploma, master, bachelor
Image Computational fluid dynamics CFD
Image IO-Scan - Integral measuring optical scanning method
Image Cryostats, Non-Metallic and Metallic

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects