Current research projects

Image Pulse-Tube-Refrigerator with sealed compressor
Image Multifunctional electronic modules for cryogenic applications
Image Micro heat exchangers in refrigeration
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Cool Up
Image Laseroptical measurement
Image Heat2Power
Image Cryostats, Non-Metallic and Metallic
Image Calibration of Low Temperature Sensors
Image IO-Scan - Integral measuring optical scanning method
Image Non- invasive flow measurements
Image Corrosion inhibitor for ammonia absorption systems
Image Intelligent innovative power supply for superconducting coils
Image Calibration leak for the water bath leak test

You are here:   /  Home


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects

Image

Humidifier System for High-Purity Gases

Nafion - moisture transfer

Image

Behavior of multiphase cryogenic fluids

experimental und numerical investigations

Image

Innovative Parahydrogen Generator Based on Magnets

Magnetic Gas Separation of the Hydrogen Isomers

Image

Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K

high performance efficiency, environmental friendliness, compactness, cost-effectiveness