Current research projects

Image Modular storage system for solar cooling
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Low Temperature Measuring Service
Image Humidifier System for High-Purity Gases
Image Investigation according to DIN EN ISO 14903
Image Laseroptical measurement
Image Energy efficiency consulting - cogeneration systems
Image Reduction of primary noise sources of fans
Image Measurements on ceiling mounted cooling systems
Image Non- invasive flow measurements
Image Air-flow test rig for fan characteristic measurement
Image Software for test rigs
Image Reducing the filling quantity
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Range of services laboratory analyses
Image Multifunctional electronic modules for cryogenic applications

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Software for technical building equipment

Design cooling load and energetic annual simulation (VDI 2078, VDI 6007, VDI 6020)

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C