Current research projects

Image Certifiable connection types in cryogenics
Image Thermostatic Expansion Valves
Image Modular storage system for solar cooling
Image Behavior of multiphase cryogenic fluids
Image Multifunctional electronic modules for cryogenic applications
Image Test rigs for refrigeration and heat pump technology
Image Heat2Power
Image Brine (water)-water heat pump
Image Laseroptical measurement
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Thermal engines
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Low Temperature Measuring Service
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Solar Cooling
Image Measurements on ceiling mounted cooling systems

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Mass Spectrometer

Determining the composition of gas mixtures in the high or ultra-high vacuum range

Image

Tensile and compression testing

Determination of yield strength, tensile strength and elongation at break

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Cool Up

Upscaling Sustainable Cooling

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process