Current research projects

Image Air-water heat pumps
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Mass Spectrometer
Image Behavior of multiphase cryogenic fluids
Image Corrosion inhibitor for ammonia absorption systems
Image Verification of storage suitability of cryo tubes
Image Innovative Parahydrogen Generator Based on Magnets
Image Measurements on ceiling mounted cooling systems
Image Calibration leak for the water bath leak test
Image Energy efficiency consulting - cogeneration systems
Image Lifetime prediction of hermetic compressor systems
Image Reduction of primary noise sources of fans
Image Thermostatic Expansion Valves
Image Brine (water)-water heat pump
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Investigation of materials

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Practical training, diploma, master, bachelor

Student training - Education at ILK

Image

Test procedures for electrical components

Insulating properties of hermetic compressors

Image

3D - Air flow sensor

Anemometer for determination of 3d-air flow