Current research projects

Image Measurements on ceiling mounted cooling systems
Image Air-water heat pumps
Image Intelligent innovative power supply for superconducting coils
Image Practical training, diploma, master, bachelor
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Cool Up
Image Reduction of primary noise sources of fans
Image Performance tests of refrigerant compressors
Image Investigation of materials
Image Thermal engines
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Innovative Parahydrogen Generator Based on Magnets
Image Hydrogen and methane testing field at the ILK
Image Testzentrum PLWP at ILK Dresden
Image Innovative small helium liquefier

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures