Current research projects

Image Panel with indirect evaporative cooling via membrane
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Hydrogen and methane testing field at the ILK
Image Humidifier System for High-Purity Gases
Image Thermal engines
Image Testing of mobile leak detectors according to DIN EN 14624
Image Calibration leak for the water bath leak test
Image Helium extraction from natural gas
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Ionocaloric cooling
Image IO-Scan - Integral measuring optical scanning method
Image Software modules
Image Test rigs for refrigeration and heat pump technology
Image Electrical components in refrigeration circuits

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Humidifier System for High-Purity Gases

Nafion - moisture transfer

Image

Behavior of multiphase cryogenic fluids

experimental und numerical investigations

Image

Innovative Parahydrogen Generator Based on Magnets

Magnetic Gas Separation of the Hydrogen Isomers

Image

Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K

high performance efficiency, environmental friendliness, compactness, cost-effectiveness