Current research projects

Image Humidifier System for High-Purity Gases
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Swirl-free on the move...
Image Energy efficiency consulting - cogeneration systems
Image Tensile and compression testing
Image Test procedures for electrical components
Image Investigation of material-dependent parameters
Image Measurement of insulated packaging
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image High temperature heat pump
Image Computational fluid dynamics CFD
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Helium extraction from natural gas
Image Hydrogen and methane testing field at the ILK
Image Intelligent innovative power supply for superconducting coils

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³