Current research projects

Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Tensile and compression testing
Image Solar Cooling
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Range of services laboratory analyses
Image Low temperature – test facilities
Image Corrosion inhibitor for ammonia absorption systems
Image Ionocaloric cooling
Image Laseroptical measurement
Image Cryostats, Non-Metallic and Metallic
Image Influenced melting point of water by magnetic field
Image Micro heat exchangers in refrigeration
Image Modular storage system for solar cooling
Image Certifiable connection types in cryogenics
Image Investigation of material-dependent parameters
Image Pulse-Tube-Refrigerator with sealed compressor

You are here:   /  Home


Hybrid- Fluid for CO2-Sublimation Cycle

Dr. Joachim Germanus

+49-351-4081-5412

Cryogenic cooling by CO2 sublimation

The objective of the research project is the selection and qualification of a new refrigeration fluid. The so called “Hybrid-Fluid” should be used both as a lubricant for compressor lubrication and as a heat transfer fluid in a CO2 sublimator. Such a fluid is a requirement for the implementation of a closed low GWP CO2 sublimation refrigeration cycle. It could be used as a replacement for previous high-GWP cold steam refrigeration cycles in a temperature range down to -80 °C.

The project idea is based on the intension to find a fluid that combines the advantages of compressor lubrication and heat transfer in a sublimator. It has to be clarified which fluid fulfill these requirements best. It would be advantageous to use a fluid which has a good solubility for CO2 at low temperatures in order to achieve a lower viscosity for a better flow characteristic in the sublimator. In addition, the viscosity should allow sufficient lubrication of the compressor under CO2 compression. On the other hand, a fluid with low solubility of CO2 would not contribute to the improved viscosity reduction in the sublimator but would show advantages for lubrication of the compressor instead.

Areas of application for cooling temperatures below -50 °C are numerous. Examples include applications in the fields of environmental simulation, medical and pharmaceutical technology, cryopreservation, freeze-drying and food technology. Upon successful completion of the research project, an important prerequisite for operating closed sublimation refrigeration cycles will be created to replace R-23 with the environmentally friendly refrigerant CO2 in a range of different applications.

In the refrigeration market in the EU currently a shortage of fluorinated refrigerants with high global warming potential (GWP) values is observed. This goes along with rising prices which have already reached several hundred Euros per kilogram for the low temperature refrigerant R-23. No relief is expected since with the commencement of the EU F-Gas Regulation in 2015 emission reduction provisions have been made which are binding for the next decades. Thus, pressure on affected manufacturers is growing to look for replacement refrigerants for their applications. However, for cooling temperatures below -50 °C, there are currently no non-flammable refrigerant alternatives. The CO2 sublimation is a suitable way to realize cooling temperatures below -50 °C with a non-flammable refrigerant.


Your Request

Further Projects

Image

Low Temperature Tribology

Tribological studies at cryogenic temperatures

Image

Investigation of coolants

Secondary loop refrigerants

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Reduction of primary noise sources of fans

...using numerical and experimental methods with contra-rotating axial fan