Current research projects

Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Intelligent innovative power supply for superconducting coils
Image Measurements on ceiling mounted cooling systems
Image Practical training, diploma, master, bachelor
Image Performance tests of condensing units
Image Testing of mobile leak detectors according to DIN EN 14624
Image Cryostats, Non-Metallic and Metallic
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Reduction of primary noise sources of fans
Image Micro fluidic expansion valve
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image IO-Scan - Integral measuring optical scanning method
Image Reducing the filling quantity
Image Air-water heat pumps
Image Filter Tests
Image Innovative Parahydrogen Generator Based on Magnets

You are here:   /  Home


Hydrogen and methane testing field at the ILK

BMWi

Dr. Andreas Kade

+49-351-4081-5117

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

ILK Dresden operates an innovative testing ground for cryogenic high-pressure applications with hydrogen (H2), methane (CH4), and methane–hydrogen mixtures. With this, different services can be offered, among other things:

  • Test and qualification of components at temperatures ranging from 20 K (−253 °C) to room temperature and pressures ranging from high vacuum to 1000 bar (e.g. test of sealings, permeation tests).
  • Investigation of charge and discharge processes at cryogenic or room-temperature-operated storage systems for hydrogen and methane (e.g. adsorber storage systems, cryo-compressed hydrogen).
  • Investigation of catalyst materials for the ortho–para conversion of hydrogen.
  • Long-time thermal charging of components and materials in hydrogen or methane atmosphere at up to +200 °C and up to 160 bar for investigating degradation effects (e.g. hydrogen embrittlement).
  • Development of different hydrogen and methane components (e.g. recooling systems, latent-heat storage systems, cryogenic pressure storage systems, heat exchangers, cryogenic pumps).
  • Realisation of complete-system solutions for hydrogen and methane.

The following diagram depicts the specific storage density that can be achieved depending on temperature and pressure:


Your Request

Further Projects

Image

Mass Spectrometer

Determining the composition of gas mixtures in the high or ultra-high vacuum range

Image

Tensile and compression testing

Determination of yield strength, tensile strength and elongation at break

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Cool Up

Upscaling Sustainable Cooling

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process