Current research projects

Image Modular storage system for solar cooling
Image Software modules
Image Humidifier System for High-Purity Gases
Image Air-flow test rig for fan characteristic measurement
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Electrical components in refrigeration circuits
Image Swirl-free on the move...
Image Computational fluid dynamics CFD
Image Practical training, diploma, master, bachelor
Image Energy efficiency consulting - cogeneration systems
Image Low noise and non metallic liquid-helium cryostat
Image Non- invasive flow measurements
Image Service offer for Leak Detection and Tightness Test
Image High Capacity Pulse Tube Cooler
Image Corrosion inhibitor for ammonia absorption systems

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request