Current research projects

Image Behavior of multiphase cryogenic fluids
Image Low Temperature Tribology
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Range of services laboratory analyses
Image Measurement of insulated packaging
Image Testing of mobile leak detectors according to DIN EN 14624
Image Solar Cooling
Image Corrosion inhibitor for ammonia absorption systems
Image Humidifier System for High-Purity Gases
Image Investigation of material-dependent parameters
Image Mass Spectrometer
Image Filter Tests
Image Testzentrum PLWP at ILK Dresden
Image Influenced melting point of water by magnetic field
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Cool Up

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Software modules

Software for properties of refrigerants

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS