Current research projects

Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Helium extraction from natural gas
Image High temperature heat pump
Image Innovative small helium liquefier
Image Filter Tests
Image Hydrogen and methane testing field at the ILK
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Service offer for Leak Detection and Tightness Test
Image High Capacity Pulse Tube Cooler
Image Pulse-Tube-Refrigerator with sealed compressor
Image Investigation of materials
Image Corrosion inhibitor for ammonia absorption systems
Image Air-flow test rig for fan characteristic measurement
Image Low Temperature Measuring Service
Image Intelligent innovative power supply for superconducting coils
Image Behavior of multiphase cryogenic fluids

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Intelligent innovative power supply for superconducting coils

Compact, powerful power supply with 4-quadrant converter

Image

Laseroptical measurement

PIV and LDA / PDA

Image

Multifunctional electronic modules for cryogenic applications

Electronic with less wiring effort - more than 100 sensors via one feedthrough

Image

Certifiable connection types in cryogenics

Detachable and permanent connections, adhesive bond / form closure / force closure

Image

Combined building and system simulation

Scientific analysis of thermodynamic processes in buildings and its systems