Current research projects

Image Mass Spectrometer
Image Innovative Parahydrogen Generator Based on Magnets
Image Service offer for Leak Detection and Tightness Test
Image Filter Tests
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Low Temperature Tribology
Image IO-Scan - Integral measuring optical scanning method
Image Investigation of materials
Image Practical training, diploma, master, bachelor
Image Measurements on ceiling mounted cooling systems
Image Influenced melting point of water by magnetic field
Image Testing of mobile leak detectors according to DIN EN 14624
Image Swirl-free on the move...
Image Measurement of insulated packaging
Image Performance tests of condensing units

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Mass Spectrometer

Determining the composition of gas mixtures in the high or ultra-high vacuum range

Image

Tensile and compression testing

Determination of yield strength, tensile strength and elongation at break

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Cool Up

Upscaling Sustainable Cooling

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process