Current research projects

Image Calibration leak for the water bath leak test
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Electrical components in refrigeration circuits
Image Innovative Parahydrogen Generator Based on Magnets
Image Micro fluidic expansion valve
Image Air-water heat pumps
Image Test rigs for refrigeration and heat pump technology
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Thermostatic Expansion Valves
Image Helium extraction from natural gas
Image Air-flow test rig for fan characteristic measurement
Image Non- invasive flow measurements
Image Investigation of materials
Image Verification of storage suitability of cryo tubes
Image Range of services laboratory analyses
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Investigation of materials

Investigations regarding the compatibility of materials with refrigerants, oils and heat transfer fluids

Image
Image

Non- invasive flow measurements

PDPA - flow fields and particle sizes

Image

Computational fluid dynamics CFD

Scientific analysis of flows