Current research projects

Image Intelligent innovative power supply for superconducting coils
Image High temperature heat pump
Image Panel with indirect evaporative cooling via membrane
Image Filter Tests
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Software modules
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Verification of storage suitability of cryo tubes
Image Ice Slurry Generation
Image Behavior of multiphase cryogenic fluids
Image State of system and failure analyses
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Software for technical building equipment
Image Cryostats, Non-Metallic and Metallic

You are here:   /  Home


IO-Scan - Integral measuring optical scanning method

INNO-KOM

02/2022 - 07/2024

M.Sc. Rebekka Grüttner

+49-351-4081-5314

IO-Scan

Development of a photometric measurement method for determining the air exchange rate in indoor areas

Motivation

  • Cost-effective, real-time assessment of indoor air quality in the form of air exchange rates
  • Verify and optimise the effectiveness of ventilation systems in occupied areas
  • Ability to evaluate aerosol reduction through the interaction of window ventilation, building ventilation system and mobile room air cleaners

Project Objective

  • Self-calibrating measuring system
  • Deviation from previous trace gas measurements should be within 10%.
  • Real-time results can detect and evaluate the influence of changes in the ventilation system during the measurement process
  • Intended measurement depth in the room: 1 m to 50 m

Solution Approach

  • The introduction of mist aerosols into the room air influences the light transmittance to be measured.
  • Transmittance of an air-aerosol mixture and use of measured transmittance to determine air exchange rate
  • Integral real-time optical measurement over individual indoor distances

Your Request

Further Projects

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

Micro heat exchangers in refrigeration

3D-printing of micro heat exchangers

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination