Current research projects

Image Electrical components in refrigeration circuits
Image Software for test rigs
Image Service offer for Leak Detection and Tightness Test
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Calibration of Low Temperature Sensors
Image High Capacity Pulse Tube Cooler
Image Lifetime prediction of hermetic compressor systems
Image Modular storage system for solar cooling
Image Multifunctional electronic modules for cryogenic applications
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Tensile and compression testing
Image Test rigs for refrigeration and heat pump technology
Image Ionocaloric cooling
Image Behavior of multiphase cryogenic fluids
Image Tribological investigations of oil-refrigerant-material-systems

You are here:   /  Home


Low noise and non metallic liquid-helium cryostat

Industry and Research Institutes

Dr. rer. nat. Andreas Kade

+49-351-4081-5117

Low-noise Magnetic Field Cryostat for SQUID-Applications

Technical Data for the Cryostats

parametervalue
volume of liquid helium5 to 12 litre (other volume possible)
time to complete evaporation of helium3 to 7 days (depends on size)
heat load0.1 W (in standby operation)
rate of helium evaporation≤ 3 litre / day
holding time of the liquid heliumup to 4 days without refilling
initial noise of the cryostat< 3 fT / Hz½
helium leak test (He-vessel)< 1 × 10-11 mbar l / s

ILK Dresden developed low noise magnetic field and non metallic helium cryostats made of GRP (glass reinforced plastics) with a high helium and vacuum holding time.

The cryostats can operate in a direction independent operation mode (tiltable arrangement) and hence they are suitable for a plurality of several applications.

The ILK concept offers much lower permeation rates inside the He-reservoir as comparable models from other manufacturers and is therefore perfect for SQUID (superconducting quantum interference device) applications and other long-term measurements.
 
The technical design of the cryostats is thus predestined for future sensor generation.

Specification

  • suitable for the cooling of SQUID-Sensors
  • non-metallic (GRP)
  • fast filling with LHe via thermosiphon
  • GRP exhaust gas cooled radiation shield for high efficiency.
  • small cold-warm distance feasible
  • low maintenance 
  • other design variants possible on costumer request

Low noise magnetic field

The low-noise magnetic field of the cryostat was tested in the magnetically shielded room BMSR-1 of PTB Berlin and is smaller than the lowest resolution limit of the measurement system used, see figure below.