Current research projects

Image Behavior of multiphase cryogenic fluids
Image Brine (water)-water heat pump
Image Test rigs for refrigeration and heat pump technology
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Heat2Power
Image Investigation of materials
Image Corrosion inhibitor for ammonia absorption systems
Image Innovative small helium liquefier
Image Performance tests of condensing units
Image Helium extraction from natural gas
Image Air-water heat pumps
Image Micro fluidic expansion valve
Image Certifiable connection types in cryogenics
Image Electrical components in refrigeration circuits
Image High Capacity Pulse Tube Cooler
Image Development of test methods and test rigs for stationary integrated refrigeration units

You are here:   /  Home


Measurement of insulated packaging

Industry

A. Illgen

+49-351-4081-5216

How efficient is my cool box?

Nowadays, more and more goods to be cooled, such as food or medicines, are being shipped. In order to ensure a continuous cold chain for these mostly small units, the goods are packed in insulated boxes without active cooling. In some cases, passive cold accumulators in the form of freezer packs are also packed.

We support the industry in the evaluation and continuous improvement of this packaging. Therfore we offer the following services:

  • Measurement of heat transition coefficient (k-Value) of the insulated boxes / containers according to DIN EN 17066 in suitable climate chambers.
  • Measurement to determine the maximum cooling time of the insulated boxes / containers with loading and freezer packs, if necessary.
  • Consulting to improve insulated boxes / containers and freezer packs.

All Measurements are carried out in close coordination with the costumer. Different calibrated measurement systems and data loggers are available. The measurements will be carried out at constant temperature or specified temperature profiles. Various packages according to DIN EN 62552 with gel filling are available for simulating the goods / loading of the insulated boxes. Thermal images can also be taken to identify thermal bridges.


Your Request

Further Projects

Image

Characterisation of Superconductors in Hydrogen Atmosphere

Are superconductors really compatible with hydrogen?

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

Development of a Cryogenic Magnetic Air Separation Unit

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Image

Software for test rigs

Individual software for complex tests and evaluation