Current research projects

Image Practical training, diploma, master, bachelor
Image Certifiable connection types in cryogenics
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Thermostatic Expansion Valves
Image High Capacity Pulse Tube Cooler
Image Test rigs for refrigeration and heat pump technology
Image Test procedures for electrical components
Image Calibration of Low Temperature Sensors
Image Low temperature – test facilities
Image Innovative Parahydrogen Generator Based on Magnets
Image Energy efficiency consulting - cogeneration systems
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Reduction of primary noise sources of fans
Image Non- invasive flow measurements
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Brine (water)-water heat pump

You are here:   /  Home


Panel with indirect evaporative cooling via membrane

INNO-KOM

01/2023 - 06/2025

Dipl.-Ing. (FH) Hannes Rosenbaum

+49-351-4081-5324

Natural Cooling Panel

Development of a decentralised cooling panel with outdoor air connection, without refrigerant, without humidity input into the room air, retrofittable and with coefficients of performance (COP) > 10

Motivation

  • GWP = 0; COP > 10; 100% renewable energy
  • Decentralised indirect evaporative cooling with no moisture in the indoor or outdoor air
  • Self-sufficient operation, rainwater harvesting
  • Radiant and convective air discharge

Project Objective

  • Application of regenerative and sustainable cooling via evaporative cooling in a decentralised air conditioning system (COP > 10)
  • Functional combination of evaporative cooling and supply of purified outdoor air
  • Novel membrane heat exchanger for two air streams and evaporation water including numerical calculation model
  • Novel convection and radiation efficient air outlet for minimum draught risk
  • Modular, cascadable unit concept for on-demand performance and off-grid and CO2-neutral operation (for PV power supply)
  • Ceiling-mounted, wall-mounted or free-standing cooling panels for residential and non-residential buildings, retrofittable and acoustically compliant

Solution Approach

  • Development of a membrane heat exchanger based on 4-layer textile laminates
  • Development of equipment based on supply air recirculation and exhaust air humidification processes
  • Development of an air outlet for convection and radiation cooling performance
  • MSR and system components for rainwater harvesting, site-independence and cascading