Current research projects

Image Ionocaloric cooling
Image Energy efficiency consulting - cogeneration systems
Image Corrosion inhibitor for ammonia absorption systems
Image Testzentrum PLWP at ILK Dresden
Image Performance tests of refrigerant compressors
Image Optimizing HVAC operation with machine learning
Image Hydrogen and methane testing field at the ILK
Image Lifetime prediction of hermetic compressor systems
Image Tribological investigations of oil-refrigerant-material-systems
Image Preformance measurements of heat exchangers
Image Low temperature – test facilities
Image Cryostats, Non-Metallic and Metallic
Image Tensile and compression testing
Image Performance tests of condensing units
Image Investigation of material-dependent parameters
Image Cool Up

You are here:   /  Home


Tensile and compression testing

Industry and research institutes

Gunar Schroeder

+49-351-4081-5129

Determination of yield strength, tensile strength and elongation at break

A tensile or compression test is a quasi-static, destructive test method for determining material characteristics such as yield strength, tensile strength and elongation at break. The specimen form and the procedure of such tests are standardized. The ISO 9862 standard defines the exact procedure and the measured variables to be recorded for metallic materials and the DIN 50125 standard defines the specimen shape and its production method. In addition, the arrangement can generally be used to record force-displacement curves with high accuracy.

To carry out the test, the specimens are clamped centrally in the grippers or positioned centrally between the compression plates. In the tensile test, the specimens are pulled apart in a defined manner. In the compression test, on the other hand, a compressive force is applied to the test specimen, e.g. rectangular prisms, cylinders or tubes, in a uniaxial stress state. In both tests, the force and change in length are recorded continuously and evaluated graphically. On request, the tensile and compression test can be carried out at very low temperatures.

Parameter Limit values samples
Materials foils, plastics, composites, metals
Typical dimension of plastic samples L×Ø: 200×10 mm (7.8"×0.4") or
L×W×H: 200×10×10 mm (7.8"×0.4"×0.4")
Measurement range of force and displacement ±5 kN (±1124 lbf), 400 mm (15.8")
Standardized testing force-distance, force-time, tension-extension

 


Your Request

Further Projects

Image

Heat2Power

Refining of fuel cell waste heat

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?