Current research projects

Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Cryostats, Non-Metallic and Metallic
Image Service offer for Leak Detection and Tightness Test
Image Tribological investigations of oil-refrigerant-material-systems
Image Pulse-Tube-Refrigerator with sealed compressor
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image High Capacity Pulse Tube Cooler
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Mass Spectrometer
Image Calibration of Low Temperature Sensors
Image Heat2Power
Image Preformance measurements of heat exchangers
Image All-in-one device for freeze-drying and production of biomaterial
Image Laseroptical measurement

You are here:  Home /  Consulting, Expert Opinions


Preformance measurements of heat exchangers

Industry

Dipl.-Ing. Markus Müller

+49-351-4081-5218

Is the heat exchanger properly sized?

We support the industry to improve the efficiency of components for cooling systems and heat pumps.

The ILK Dresden offers the following services:

We determine the preformance and pressure losses of plate heat exchangers (evaporators and condensors) or other heat exchangers for liquids in a defined range.
The measurment is based on the following norms

  • DIN EN 306 Heat exchangers - Methods of measuring the parameters necessary for establishing the performance
  • DIN EN 1117 Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for establishing the performance
  • DIN EN 1118 Heat exchangers - Refrigerant cooled liquid coolers - Test procedure for establishing the performance

The test are preformed at a special developed test rig, which can be seen on the following picture.

Operation range of the test rig

  • Kältemittel: Refrigerants: R134a, R404a, R407C, R410A, R507, (others on request)
  • Coolant: Brine
  • Heat carrier: Water
  • Maximum Performance condensor: 70 kW
  • Maximum Performance evaporator: 60 kW

The measurement systems are calibrated regularly.

Additional services

We can support you at following tasks

  • Technical design of components
  • Optimisation of components
  • Software development for technical design and optimisation

Also we can offer you

  • static and time-varying thermal simulations
  • thermography of components

The ILK Dresden has many expertise and a high flexibility in the field of air and refrigeration technology. You will benefit from the broad spectrum of our research directions and technologies as well as the integration of various fields of expertise.


Your Request

Further Projects - Consulting, Expert Opinions

Image

Measurement of insulated packaging

How efficient is my cool box?

Image

Energy efficiency consulting - cogeneration systems

How efficient is my refrigeration system?

Image

Investigation of coolants

Secondary loop refrigerants

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Software for technical building equipment

Design cooling load and energetic annual simulation (VDI 2078, VDI 6007, VDI 6020)