Current research projects

Image Preformance measurements of heat exchangers
Image Cold meter
Image Software for technical building equipment
Image Corrosion inhibitor for ammonia absorption systems
Image Practical training, diploma, master, bachelor
Image Micro fluidic expansion valve
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Optimizing HVAC operation with machine learning
Image Ionocaloric cooling
Image Modular storage system for solar cooling
Image Verification of storage suitability of cryo tubes
Image Brine (water)-water heat pump
Image High temperature heat pump
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures

You are here:  Home /  Measurements and Tests


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects - Measurements and Tests

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS

Image

Investigation of coolants

Secondary loop refrigerants

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement