Current research projects

Image Hydrogen and methane testing field at the ILK
Image Investigation of materials
Image Air-flow test rig for fan characteristic measurement
Image Innovative small helium liquefier
Image Innovative Parahydrogen Generator Based on Magnets
Image Micro heat exchangers in refrigeration
Image Multifunctional electronic modules for cryogenic applications
Image High Capacity Pulse Tube Cooler
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Calibration leak for the water bath leak test
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Reducing the filling quantity
Image Test procedures for electrical components
Image Measurements on ceiling mounted cooling systems
Image Intelligent innovative power supply for superconducting coils
Image Investigation of material-dependent parameters

You are here:  Home /  Measurements and Tests


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects - Measurements and Tests