IO-Scan - Integral measuring optical scanning method

INNO-KOM

02/2022 - 07/2024

M.Sc. Rebekka Grüttner

+49-351-4081-5314

IO-Scan

Development of a photometric measurement method for determining the air exchange rate in indoor areas

Motivation

  • Cost-effective, real-time assessment of indoor air quality in the form of air exchange rates
  • Verify and optimise the effectiveness of ventilation systems in occupied areas
  • Ability to evaluate aerosol reduction through the interaction of window ventilation, building ventilation system and mobile room air cleaners

Project Objective

  • Self-calibrating measuring system
  • Deviation from previous trace gas measurements should be within 10%.
  • Real-time results can detect and evaluate the influence of changes in the ventilation system during the measurement process
  • Intended measurement depth in the room: 1 m to 50 m

Solution Approach

  • The introduction of mist aerosols into the room air influences the light transmittance to be measured.
  • Transmittance of an air-aerosol mixture and use of measured transmittance to determine air exchange rate
  • Integral real-time optical measurement over individual indoor distances

Your Request

Further Projects - Measurements and Tests

Image

Mass Spectrometer

Determining the composition of gas mixtures in the high or ultra-high vacuum range

Image

Tensile and compression testing

Determination of yield strength, tensile strength and elongation at break

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures