Current research projects

Image High Capacity Pulse Tube Cooler
Image Performance tests of condensing units
Image Energy efficiency consulting - cogeneration systems
Image Preformance measurements of heat exchangers
Image Test rigs for refrigeration and heat pump technology
Image Ionocaloric cooling
Image Lifetime prediction of hermetic compressor systems
Image Testing of mobile leak detectors according to DIN EN 14624
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Software modules
Image State of system and failure analyses
Image Range of services laboratory analyses
Image Intelligent innovative power supply for superconducting coils
Image Thermal engines
Image Investigation of materials
Image Solar Cooling

You are here:  Home /  Measurements and Tests


Performance tests of refrigerant compressors

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does your compressor perform well?

The Test center PWLP supports the industry in the development of environmentally friendly, energy-efficient vapor-compression refrigeration system and compression heat pumps. In practice, the F-Gas Regulation EU 517/2014 means the increased use of flammable refrigerants (KM) of classes A2 and A3.

The ILK Dresden offers the following services for you:

Investigation of compressor parameters

For a defined application map of open, semi-hermetic or hermetic respectively one or two stage refrigerant compressors we determine the refrigerating capacity, power absorbed, COP, volumetric and isentropic efficiency.

For a defined application map, we determine according to the standards
DIN EN 13771-1 and DIN EN 12900 the

Cooling capacity, drive power, COP, delivery and quality level

Now also for flammable refrigerants like propane!

We determine the parameters for

  • one- or two-stage (with integrated ECONOMISER),
  • semi-hermetic or
  • hermetic compressors
  • types: reciprocating or rolling piston, scroll compressors

The ASEREP property library from ASERCOM is the source of the refrigerant property values

Displacement [m³/h] Refrigerating capacity [kW]Refrigerants
50..200...200

A1: R134a, R1234yf, R404A, R407A, R407C, R407F, R448A, R513A, R152a, R452A, etc.

3...30...25A2L/A2: R452B, R32, R1234yf, R1234ze
3...30...25A3: R290 (Propane)

Current calibrations of the measuring systems are a matter of course.
Within the scope of our flexible accreditation, further measuring tasks can be realized according to applicable test standards.

Compressor service life study

We test the thermal / mechanical long-term behavior and the interaction between compressor, refrigerant (A1, A2 / L and A3) and oil

in the LifeTimeTest LTT500

  • according to the individual requirement of the customer or
  • according to our ILK standard procedure over approx. 500 h:
    • with defined variable loads in the compressors operating map (stress level 1… 6)
    • when the permissible operating parameters are exceeded (on / off cycles, reduced overheating, oscillation, liquid) and with analysis of the development over time of the compressor parameters at the reference point (according to DIN EN 13771-1).

Examination of the compressor and oil condition

We check in a condition analysis of the compressor

  • possible damage from field use or after completing a LifeTimeTest LTT500
  • based on macroscopic mechanical wear characteristics, electrical properties of the electric motor and oil condition
  • optionally with technical evaluation of the compressor according to Guideline VDI 2225 (objectification of characteristics without directly measurable comparison parameters).

Forschung und Entwicklung

Das ILK Dresden ist seit vielen Jahren auf dem Gebiet der Entwicklung und Prüfung von Kälte- und Wärmepumpentechnik tätig. Die Entwicklungsarbeit wird individuell und in enger Zusammenarbeit mit dem Auftraggeber geleistet.

Das ILK Dresden besitzt ein langjähriges Know-how in der Untersuchung von Kältemittelverdichtern. Das notwendige Know-how für die Bewertung der Maschinen wurde insbesondere in den Förderprojekten erarbeitet:

  • "Energieeffizienz von Kältemittelverdichtern", (BMWi EN FKZ IW073034),
  • "Mehrfach-Zwischeneinspritzung an Rollkolbenverdichtern", (BMWi EN FKZ VF120022),
  • "Prüfstand und Prüfverfahren für Verflüssigungssätze" (BMWi EN FKZ MF150072)
  • "Verfahren für Verdichterschutz", (BMWi EN FKZ MF150165).

In diesen Projekten wurden insbesondere Erkenntnisse zu folgenden Themen gewonnen, die eine fachgerechte Interpretation der Ergebnisse ermöglichen:

  • konstruktiver Aufbau unterschiedlicher Verdichterkonstruktionen
  • Verläufe von Gütegrad und Liefergrad als Funktion von Verdichterbauart und Kennfeld
  • Leistungsmessverfahren mit reduzierter Messunsicherheit an Verdichtern unterschiedlicher Bauarten
  • Entwicklung von Kälteleistung, Antriebsleistung und COP in Abhängigkeit von Bauart und Einsatzbedingungen
  • Verhältnisse von äußeren und inneren Bedingungen des Verdichtungsprozesses und Auswirkungen auf die Definition von vergleichenden Kennwerten
  • Verfahren zur Bestimmung des Ölanteils im Kältemittelmassenstrom

Your Request

Further Projects - Measurements and Tests

Image

Laseroptical measurement

PIV and LDA / PDA

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?