Current research projects

Image Optimizing HVAC operation with machine learning
Image Modular storage system for solar cooling
Image Reduction of primary noise sources of fans
Image Service offer for Leak Detection and Tightness Test
Image Lifetime prediction of hermetic compressor systems
Image Development of a Cryogenic Magnetic Air Separation Unit
Image State of system and failure analyses
Image Electrical components in refrigeration circuits
Image Behavior of multiphase cryogenic fluids
Image Testzentrum PLWP at ILK Dresden
Image Low temperature – test facilities
Image Software for technical building equipment
Image Test procedures for electrical components
Image Low Temperature Tribology
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Helium extraction from natural gas

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures

Image

Test procedures for electrical components

Insulating properties of hermetic compressors