Current research projects

Image All-in-one device for freeze-drying and production of biomaterial
Image Low Temperature Measuring Service
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Low noise and non metallic liquid-helium cryostat
Image Hydrogen and methane testing field at the ILK
Image Filter Tests
Image Air-flow test rig for fan characteristic measurement
Image Testing of mobile leak detectors according to DIN EN 14624
Image Humidifier System for High-Purity Gases
Image Micro fluidic expansion valve
Image Certifiable connection types in cryogenics
Image Service offer for Leak Detection and Tightness Test
Image Mass Spectrometer
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Range of services laboratory analyses
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings

You are here:  Home /  Research and Development


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects - Research and Development

Image

High Capacity Pulse Tube Cooler

for Cryogenic High-Power Applications

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology