Current research projects

Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Combined building and system simulation
Image Panel with indirect evaporative cooling via membrane
Image Low Temperature Measuring Service
Image Corrosion inhibitor for ammonia absorption systems
Image Verification of storage suitability of cryo tubes
Image Investigation according to DIN EN ISO 14903
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Testzentrum PLWP at ILK Dresden
Image Energy efficiency consulting - cogeneration systems
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Performance tests of refrigerant compressors
Image Software for test rigs
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Humidifier System for High-Purity Gases
Image Certifiable connection types in cryogenics

You are here:  Home /  Research and Development


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Research and Development

Image

High Capacity Pulse Tube Cooler

for Cryogenic High-Power Applications

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology