Current research projects

Image Thermostatic Expansion Valves
Image Investigation according to DIN EN ISO 14903
Image IO-Scan - Integral measuring optical scanning method
Image Practical training, diploma, master, bachelor
Image Performance tests of refrigerant compressors
Image High temperature heat pump
Image Multifunctional electronic modules for cryogenic applications
Image Influenced melting point of water by magnetic field
Image Panel with indirect evaporative cooling via membrane
Image Software for technical building equipment
Image Computational fluid dynamics CFD
Image All-in-one device for freeze-drying and production of biomaterial
Image Laseroptical measurement
Image Electrical components in refrigeration circuits
Image Helium extraction from natural gas
Image Measurement of insulated packaging

You are here:  Home /  Research and Development


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction

Your Request

Further Projects - Research and Development