You are here: Home / Research and Development
Performance tests of refrigerant compressors
![](/fileadmin/user_upload/Artikel/2013/Prueflabor_Waermepumpen/PLWP2018/projekt_verdichter.jpg)
Does your compressor perform well?
The Test center PWLP supports the industry in the development of environmentally friendly, energy-efficient vapor-compression refrigeration system and compression heat pumps. In practice, the F-Gas Regulation EU 517/2014 means the increased use of flammable refrigerants (KM) of classes A2 and A3.
The ILK Dresden offers the following services for you:
Investigation of compressor parameters
For a defined application map of open, semi-hermetic or hermetic respectively one or two stage refrigerant compressors we determine the refrigerating capacity, power absorbed, COP, volumetric and isentropic efficiency.
For a defined application map, we determine according to the standards
DIN EN 13771-1 and DIN EN 12900 the
Cooling capacity, drive power, COP, delivery and quality level
Now also for flammable refrigerants like propane!
We determine the parameters for
- one- or two-stage (with integrated ECONOMISER),
- semi-hermetic or
- hermetic compressors
- types: reciprocating or rolling piston, scroll compressors
The ASEREP property library from ASERCOM is the source of the refrigerant property values
Displacement [m³/h] | Refrigerating capacity [kW] | Refrigerants |
50..200 | ...200 | A1: R134a, R1234yf, R404A, R407A, R407C, R407F, R448A, R513A, R152a, R452A, etc. |
3...30 | ...25 | A2L/A2: R452B, R32, R1234yf, R1234ze |
3...30 | ...25 | A3: R290 (Propane) |
Current calibrations of the measuring systems are a matter of course.
Within the scope of our flexible accreditation, further measuring tasks can be realized according to applicable test standards.
Compressor service life study
We test the thermal / mechanical long-term behavior and the interaction between compressor, refrigerant (A1, A2 / L and A3) and oil
in the LifeTimeTest LTT500
- according to the individual requirement of the customer or
- according to our ILK standard procedure over approx. 500 h:
- with defined variable loads in the compressors operating map (stress level 1… 6)
- when the permissible operating parameters are exceeded (on / off cycles, reduced overheating, oscillation, liquid) and with analysis of the development over time of the compressor parameters at the reference point (according to DIN EN 13771-1).
Examination of the compressor and oil condition
We check in a condition analysis of the compressor
- possible damage from field use or after completing a LifeTimeTest LTT500
- based on macroscopic mechanical wear characteristics, electrical properties of the electric motor and oil condition
- optionally with technical evaluation of the compressor according to Guideline VDI 2225 (objectification of characteristics without directly measurable comparison parameters).
![Test rig up to 15 kW refrigerating capacity](/fileadmin/user_upload/Artikel/2013/Prueflabor_Waermepumpen/PLWP2018/PLWP-Gasschleife_klein.png)
![Test rig up to 100 kW refrigerating capacity](/fileadmin/user_upload/Artikel/2013/Prueflabor_Waermepumpen/PLWP2018/PLWP-Gasschleife_gross.png)
Forschung und Entwicklung
Das ILK Dresden ist seit vielen Jahren auf dem Gebiet der Entwicklung und Prüfung von Kälte- und Wärmepumpentechnik tätig. Die Entwicklungsarbeit wird individuell und in enger Zusammenarbeit mit dem Auftraggeber geleistet.
Das ILK Dresden besitzt ein langjähriges Know-how in der Untersuchung von Kältemittelverdichtern. Das notwendige Know-how für die Bewertung der Maschinen wurde insbesondere in den Förderprojekten erarbeitet:
- "Energieeffizienz von Kältemittelverdichtern", (BMWi EN FKZ IW073034),
- "Mehrfach-Zwischeneinspritzung an Rollkolbenverdichtern", (BMWi EN FKZ VF120022),
- "Prüfstand und Prüfverfahren für Verflüssigungssätze" (BMWi EN FKZ MF150072)
- "Verfahren für Verdichterschutz", (BMWi EN FKZ MF150165).
In diesen Projekten wurden insbesondere Erkenntnisse zu folgenden Themen gewonnen, die eine fachgerechte Interpretation der Ergebnisse ermöglichen:
- konstruktiver Aufbau unterschiedlicher Verdichterkonstruktionen
- Verläufe von Gütegrad und Liefergrad als Funktion von Verdichterbauart und Kennfeld
- Leistungsmessverfahren mit reduzierter Messunsicherheit an Verdichtern unterschiedlicher Bauarten
- Entwicklung von Kälteleistung, Antriebsleistung und COP in Abhängigkeit von Bauart und Einsatzbedingungen
- Verhältnisse von äußeren und inneren Bedingungen des Verdichtungsprozesses und Auswirkungen auf die Definition von vergleichenden Kennwerten
- Verfahren zur Bestimmung des Ölanteils im Kältemittelmassenstrom