Current research projects

Image Calibration leak for the water bath leak test
Image Modular storage system for solar cooling
Image Measurements on ceiling mounted cooling systems
Image High Capacity Pulse Tube Cooler
Image Software for technical building equipment
Image All-in-one device for freeze-drying and production of biomaterial
Image Humidifier System for High-Purity Gases
Image Tensile and compression testing
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Corrosion inhibitor for ammonia absorption systems
Image Cool Up
Image State of system and failure analyses
Image Test procedures for electrical components
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Performance tests of refrigerant compressors
Image Computational fluid dynamics CFD

You are here:  Home /  Research and Development


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Research and Development

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?