Current research projects

Image Testing of mobile leak detectors according to DIN EN 14624
Image All-in-one device for freeze-drying and production of biomaterial
Image Cryostats, Non-Metallic and Metallic
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Investigation of materials
Image Micro heat exchangers in refrigeration
Image Brine (water)-water heat pump
Image Preformance measurements of heat exchangers
Image Refrigerants, lubricants and mixtures
Image Service offer for Leak Detection and Tightness Test
Image Low temperature – test facilities
Image Software for test rigs
Image Combined building and system simulation
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Verification of storage suitability of cryo tubes
Image Modular storage system for solar cooling

You are here:  Home /  Research and Development


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Research and Development

Image

High Capacity Pulse Tube Cooler

for Cryogenic High-Power Applications

Image

Thermal engines

Power Generation from Waste Heat

Image

Helium extraction from natural gas

Innovative solutions for helium extraction

Image

Ice Slurry Generation

Using Direct Evaporation

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology