Current research projects

Image Cryostats, Non-Metallic and Metallic
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Non- invasive flow measurements
Image Micro fluidic expansion valve
Image Combined building and system simulation
Image Investigation according to DIN EN ISO 14903
Image Refrigerants, lubricants and mixtures
Image Investigation of material-dependent parameters
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Low Temperature Measuring Service
Image Corrosion inhibitor for ammonia absorption systems
Image Intelligent innovative power supply for superconducting coils
Image Investigation of coolants
Image Service offer for Leak Detection and Tightness Test
Image Software for test rigs

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects - Testing Equipment