Current research projects

Image Air-flow test rig for fan characteristic measurement
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Hydrogen and methane testing field at the ILK
Image Testing of mobile leak detectors according to DIN EN 14624
Image Computational fluid dynamics CFD
Image Test procedures for electrical components
Image Software for test rigs
Image Non- invasive flow measurements
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Micro heat exchangers in refrigeration
Image Measurements on ceiling mounted cooling systems
Image Thermal engines
Image Software for technical building equipment
Image Corrosion inhibitor for ammonia absorption systems
Image Preformance measurements of heat exchangers

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects - Testing Equipment

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Ice Slurry Generation

Using Direct Evaporation