Current research projects

Image Investigation of material-dependent parameters
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Low Temperature Measuring Service
Image Low Temperature Tribology
Image Investigation of coolants
Image Mass Spectrometer
Image 3D - Air flow sensor
Image Investigation of materials
Image Filter Tests
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Reducing the filling quantity
Image Corrosion inhibitor for ammonia absorption systems
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Hydrogen and methane testing field at the ILK
Image Refrigerants, lubricants and mixtures
Image Lifetime prediction of hermetic compressor systems

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³