Current research projects

Image Electrical components in refrigeration circuits
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Intelligent innovative power supply for superconducting coils
Image Tensile and compression testing
Image State of system and failure analyses
Image Cryostats, Non-Metallic and Metallic
Image Investigation of materials
Image Behavior of multiphase cryogenic fluids
Image Measurements on ceiling mounted cooling systems
Image Thermal engines
Image Range of services laboratory analyses
Image Pulse-Tube-Refrigerator with sealed compressor
Image Test procedures for electrical components
Image 3D - Air flow sensor
Image Hydrogen and methane testing field at the ILK
Image Energy efficiency consulting - cogeneration systems

You are here:  Home /  Testing Equipment


Corrosion inhibitor for ammonia absorption systems

EURONORM GmbH

07/2021-08/2023

Dr. rer. nat. Franziska Krahl

+49-351-4081-5421

An alternative to chromium(VI) compounds

Project management: Dr. Franziska Krahl, Dr. Steffen Feja

Unlike electrically driven compression chillers or compression heat pumps, ammonia absorption systems (chillers and heat pumps) are driven by thermal energy. If the thermal energy comes from solar thermal energy, geothermal energy or waste heat, for example, these machines can be operated without fossil fuels. The working substances water and ammonia used are naturally occurring compounds, do not contribute to global warming (GWP = 0) and also have no ozone depletion potential (ODP).

The research project focused on identifying a suitable corrosion inhibitor for ammonia absorption systems to replace chromium(VI) compounds. A strategy was developed to enable the investigation of a large number of potential alternatives. From a total of more than 200 substance combinations (test approaches), 12 promising alternatives for further laboratory tests were identified using a rapid test developed in the project.

The rapid test developed proved to be very efficient in terms of identifying potential corrosion inhibitors. By using sealed reaction chambers, this test can also be carried out at significantly higher temperatures, which means that conditions close to the application are already present during screening.

At the end of the research project, 3 chromium(VI)-free corrosion inhibitors for ammonia absorption systems will be available, the basic suitability of which has been proven in laboratory tests. Their effectiveness is now to be tested in demonstrators.


Your Request

Further Projects - Testing Equipment

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Ice Slurry Generation

Using Direct Evaporation