Current research projects

Image Corrosion inhibitor for ammonia absorption systems
Image Combined building and system simulation
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Test procedures for electrical components
Image Electrical components in refrigeration circuits
Image Air-flow test rig for fan characteristic measurement
Image Intelligent innovative power supply for superconducting coils
Image Investigation of material-dependent parameters
Image Range of services laboratory analyses
Image Cryostats, Non-Metallic and Metallic
Image Testzentrum PLWP at ILK Dresden
Image Tribological investigations of oil-refrigerant-material-systems
Image Test rigs for refrigeration and heat pump technology
Image Ionocaloric cooling
Image Pulse-Tube-Refrigerator with sealed compressor
Image Mass Spectrometer

You are here:  Home /  Testing Equipment


Low noise and non metallic liquid-helium cryostat

Industry and Research Institutes

Dr. rer. nat. Andreas Kade

+49-351-4081-5117

Low-noise Magnetic Field Cryostat for SQUID-Applications

Technical Data for the Cryostats

parametervalue
volume of liquid helium5 to 12 litre (other volume possible)
time to complete evaporation of helium3 to 7 days (depends on size)
heat load0.1 W (in standby operation)
rate of helium evaporation≤ 3 litre / day
holding time of the liquid heliumup to 4 days without refilling
initial noise of the cryostat< 3 fT / Hz½
helium leak test (He-vessel)< 1 × 10-11 mbar l / s

ILK Dresden developed low noise magnetic field and non metallic helium cryostats made of GRP (glass reinforced plastics) with a high helium and vacuum holding time.

The cryostats can operate in a direction independent operation mode (tiltable arrangement) and hence they are suitable for a plurality of several applications.

The ILK concept offers much lower permeation rates inside the He-reservoir as comparable models from other manufacturers and is therefore perfect for SQUID (superconducting quantum interference device) applications and other long-term measurements.
 
The technical design of the cryostats is thus predestined for future sensor generation.

Specification

  • suitable for the cooling of SQUID-Sensors
  • non-metallic (GRP)
  • fast filling with LHe via thermosiphon
  • GRP exhaust gas cooled radiation shield for high efficiency.
  • small cold-warm distance feasible
  • low maintenance 
  • other design variants possible on costumer request

Low noise magnetic field

The low-noise magnetic field of the cryostat was tested in the magnetically shielded room BMSR-1 of PTB Berlin and is smaller than the lowest resolution limit of the measurement system used, see figure below.


Your Request

Further Projects - Testing Equipment

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

3D - Air flow sensor

Anemometer for determination of 3d-air flow