Current research projects

Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Verification of storage suitability of cryo tubes
Image Measurements on ceiling mounted cooling systems
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image High temperature heat pump
Image Innovative small helium liquefier
Image Measurement of insulated packaging
Image Range of services laboratory analyses
Image Behavior of multiphase cryogenic fluids
Image Investigation according to DIN EN ISO 14903
Image Software modules
Image Cool Up
Image Development of a Cryogenic Magnetic Air Separation Unit
Image All-in-one device for freeze-drying and production of biomaterial
Image Test procedures for electrical components
Image High Capacity Pulse Tube Cooler

You are here:  Home /  Testing Equipment


Swirl-free on the move...

2019-2021

Christian Friebe

+49-351-4081-5313

project started

CFturbo

...with a contra-rotating fan

In many areas centrifugal fans are used for conveying air. Depending on the installation situation and requirements, the use of a housingless fan, a so-called free-running impeller, can be feasabile. A typical application is, for example, the air conditioning unit (see Figure 1). A disadvantage is the functionally swirling discharge from the impeller. This may lead to poorer acoustics, more pressure loss and lower performance in downstream components such as filters, silencers or heat exchangers.

According to the state of the art, the swirl can be removed from the flow by various means. On the one hand, the use of a spiral housing is possible, on the other hand, the use of discharge guidevanes are possible. The volute casing contradicts the purpose of the free-running impeller and still has a high air speed at the outlet. Both the volute casing and the guide vanes can both help to convert the existing dynamic pressure from the impeller into usable static pressure, but neither is capable of transferring additional energy to the fluid.
Therefore, the task of this research project is to create a swirl-free outflow from an impeller using a new type of contra-rotating impeller. The mode of operation shown in Figure 2 is based on the speed triangles of the two counter-rotating impellers.
On the basis of a speed and volume flow dependent coordination of the two impellers with each other, a shock-free flow is achieved with the contra-rotating design of the second impeller and the relative speed w is further decelerated. Due to the existing pre-swirl, a swirl-free pressure reduction can be achieved despite the reduction in speed.

The following subtasks must be clarified in order to successfully deal with the topic:

  • Design, tuning and optimization of the impellers
  • Development of a suitable drive concept
  • Reduction of leakage in the gap between the two impellers
  • Optimization of the acoustic properties
  • Development of a swirl detector for the control of the fan

The use of a contra-rotating centrifugal fan provides the following advantages:

  • A swirl-free outflow for higher static efficiency, comparable to a housing or a guide vane
  • Optimum flow to the downstream components from a thermodynamic and flow mechanics point of view
  • Optimum efficiency by adjusting the speeds
  • Greater performance with the same construction volume

Your Request

Further Projects - Testing Equipment

Image

Multifunctional electronic modules for cryogenic applications

Electronic with less wiring effort - more than 100 sensors via one feedthrough

Image

Cold meter

The fast way to refrigerating capacity

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units