Current research projects

Image Verification of storage suitability of cryo tubes
Image Calibration leak for the water bath leak test
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Measurement of insulated packaging
Image Test procedures for electrical components
Image Low Temperature Tribology
Image Cryostats, Non-Metallic and Metallic
Image Thermal engines
Image Reduction of primary noise sources of fans
Image State of system and failure analyses
Image Influenced melting point of water by magnetic field
Image Lifetime prediction of hermetic compressor systems
Image Helium extraction from natural gas
Image Pulse-Tube-Refrigerator with sealed compressor
Image Micro fluidic expansion valve
Image Intelligent innovative power supply for superconducting coils

You are here:  Home /  Research and Development


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Research and Development

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation

Image

Optimizing HVAC operation with machine learning

Intelligent control of HVAC systems – high comfort with low energy demand

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h