Current research projects

Image Measurements on ceiling mounted cooling systems
Image Cold meter
Image Reducing the filling quantity
Image Low Temperature Tribology
Image Modular storage system for solar cooling
Image Low Temperature Measuring Service
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Innovative small helium liquefier
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image 3D - Air flow sensor
Image Investigation according to DIN EN ISO 14903
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Optimizing HVAC operation with machine learning
Image Intelligent innovative power supply for superconducting coils
Image Air-flow test rig for fan characteristic measurement

You are here:  Home /  Testing Equipment


Multifunctional electronic modules for cryogenic applications

Euronorm GmbH

Dr. Norbert Gust

+49-351-4081-5112

Electronic with less wiring effort - more than 100 sensors via one feedthrough

The aim of the R&D project was the development of multifunctional electronic modules that enable the operation of a large number and variety of sensors to be used for cryogenic applications.

Usually, cryogenic sensors are located in cryostats and all cables have to be decoupled via feedthroughs, which leads to an increased heat input. To avoid this, we have developed and implemented various multiplexers as a part of the project, which work well under cryogenic conditions, see Figure 1 (left). The multiplexers are designed for an operation with a 10-wire bus system with arbitrary expandability. The multiplexers were developed and optimized for minimum interference, maximum function and compactness.

Another major goal of the R&D project was the development of a universal measuring bridge for any sensors, see Figure 1 (right). As a result, different electronic multifunction modules and cold multiplexers were developed, realized and validated. These modules are characterized by the fact that any sensors can be connected by means of a universal circuit board design. The selection of the modules was modular, which is why special components were selected and tested depending on the requirements. Among the options are: Different references (resistance, voltage), amplification factors, active shielding, battery operation, displays (TFT, LCD), interfaces (RS485, USB), storage options (SD card), electrical isolation, interface to multiplexers, and type of housing.

During development, special attention was paid to electromagnetic compatibility and interference sensitivity during switching operations, such as in heater control. The accuracy is determined by reference resistors and voltages. In addition, the time response of the facial expressions was a key parameter of the development in order to ensure a fast and stable measurement.

Within the R&D project a software was programmed which is available as a universal platform for any configuration of modules. The modules can be in-house developments or commercially available products. Each controller supports a freely definable number of sensors, actuators, controllers and binary inputs and outputs. Each sensor, actuator and controller can represent any common physical quantity. These include temperature, pressure, level, voltage, current, resistance etc.

With our development of a universal temperature measuring bridge, any temperature sensors can be read out with high accuracy, see Figure 2.


Your Request

Further Projects - Testing Equipment

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures

Image

All-in-one device for freeze-drying and production of biomaterial

with automated freezing and sterilisation option

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination